MTM-02-IM · 2.2 Slip and torqueWorksheet 2.2-A: torque against slip from the FEMM model of the kit motor, and the field at three slips.
The FEMM runs
At the chosen slip

Torque against slip, at rated stator current

Each point is one time-harmonic FEMM solution of the kit cross-section at the slip frequency fs = s·f, with 1.93 A rms in every phase. Pick a slip to read it.

FEMM flux density plot of the kit motor at the chosen slip

Session
MTM-02-IM · 2.3 Equivalent circuit and power flowWorksheet 2.3-A: the kit motor's circuit, its full-load point and the power flow. Then write your prediction in the Motor Logbook.
Per-phase circuit (delta, 230 V)
At this slip

The kit motor at full load

Per-phase T circuit: R1, X1 in the stator; Xm and Rc for the magnetising branch; X2′ and R2′/s for the rotor. Drag the slip.

0.080
Power flow, all three phases
Session
MTM-02-IM · 2.4 From tests to parametersWorksheet 2.4-A: the circuit from a DC test, a no-load test and a locked-rotor test (the worked dataset of the kit motor is loaded; your own motor is tested in MTM-05-IM 5.4).
DC resistance
Parameters

No-load and locked-rotor tests, motor in delta

Line values as the meters read them. Edit any cell; the parameters update. The method follows IEC 60034-28 in a simplified form: equal leakage reactances, X1 = X2′.

LabelMeaning
C ConfirmedMeasured on the kit, or from its datasheet or nameplate.
I InferredWorked out from other values. Every FEMM result and everything this app calculates is Inferred.
T Training targetChosen for the exercise. Never report it as measured.
NA Not availableNot known yet.